SYSTEM TEST SPECIFICATIONS
Transformer: 120 Vac / 60 Hz input
18 Vac / 40 VA output
10 W solar panel: 18-22 Vdc / 600 mA per hour
Battery: 12 Vdc / 7 Ah
Wire: 16 gauge, multi stranded, direct burial
Motor: 12 Vdc 90 rpm with case hardened gears. The motor current range
is 2.5 to 10 A if the gate is in good working order.
Receiver: 5 Vdc / digital communication. ONLY GTO receivers can be
connected to these terminals.
Control board: Microprocessor driven. Powered by 12 Vdc.
terminal. Then activate the unit and watch the voltmeter. The drop should not be more than 1 volt.
Note: A loose battery terminal will cause the same symptoms that a bad battery will cause. Terminals should
be secure and corrosion free.
Remote control range: This will vary at each installation. (see FCC disclaimer on page 23), but generally varies
from 50 ft. to 100 ft.
• Make sure that the receiver is located above metal fences.
• Moving the receiver even a few inches can change the range of operation.
• Move the receiver as far from the motor as possible to avoid the chance of electrical interference.
• Check or change the battery in the transmitter.